I am unable to store an ECG. The machine is saying memory is full.

The machine can store around 200 ECGs before the memory is full. We recommend deleting previously... Read More

  • About this manual This manual covers the MAC 600 with magnetic ballast and the MAC 600 E with electronic ballast. “MAC 600/E” is used to refer to both models when describing common features or procedures. This manual describes the features of software version 2.3. The latest MAC 600/E software and documentation are available.
  • The industry standard MAC 600 is a powerful wash light with a CMY color mixing system, 440° of pan and 306° of tilt and a fast and smooth movement.
  • The MAC 600 puts advanced diagnostic tools at your fingertips, enabling physicians to deliver one of the world’s best ECG analyses. And with on-screen ECG results, you have the completely digital workflow that can help you diagnose patients faster than ever before.

Martin Mac 600

I am unable to store an ECG. The machine is saying memory is full.

Manual

The machine can store around 200 ECGs before the memory is full. We recommend deleting previously stored ECGs periodically. To clear the memory on the unit, ensure that you have transferred all ECGs on the machine and follow the instructions below;
1. Ensure you have the SD card inserted into the machine.
2. Power on the machine and then press ‘F4’ for more options.
3. Press ‘F3’ to access File Manager.
4. You will now be able to see a list of all stored ECGs. To select all ECGS press ‘F2’.
5. All ECGs will now be highlighted. Press ‘F4’ for more options.
6. Press ‘F1’ to Delete.
7. You will now be prompted for a system password. Providing this has not be been changed the default is ‘1111’.
8. You will now receive a final warming message. Press ‘F2’ to confirm.

How long is the battery life on the machine?

The machine will last around 3 to 6 hours on one full charge, dependent on usage. One full charge... Read More

The machine will last around 3 to 6 hours on one full charge, dependent on usage. One full charge takes around 4 to 6 hours.

How do I change the paper?

1. Open the paper drawer located on the left of the machine. 2. Place the Z-fold paper pack in... Read More

1. Open the paper drawer located on the left of the machine.
2. Place the Z-fold paper pack inside the draw.
3. Lift the first sheet of the pack (should have an arrow printed on it with a black rectangle in the upper left corner) outside of the draw.
4. Close the paper draw.
5. The sheet if aligned correctly should now rest within the drawer’s lid.

The machine is saying SD card is write protected.

Manual For Mec 650

In the back of the machine is an SD card where all the ECGs are stored. The card itself can b... Read More

In the back of the machine is an SD card where all the ECGs are stored.
The card itself can be locked so that the data on it cannot be changed or deleted.
Occasionally this can be done by accident.
To check if the card is locked, eject the SD card from the back of the machine.
In the top left corner of the card is a tiny switch. If this switch is all the way down or in the middle then the card is locked and write protected.
Gently move the switch all the way back to the top and reinsert the SD card back into the machine.

Can I purchase additional SD cards for my machine?

Yes, you can purchase additional cards, however you need to ensure that the card(s) you buy are n... Read More

Can I purchase additional SD cards for my machine?

Yes, you can purchase additional cards, however you need to ensure that the card(s) you buy are no higher than ‘2GB’. This is due to how the machine stores ECGs on the card. SD cards of a higher capacity will not be recognised by the machine.

I am unable to gain a trace. The machine is just reporting ‘Limb lead disconnected’

This usually means that one or two of the limb leads are struggling to gain a connection with you... Read More

I am unable to gain a trace. The machine is just reporting ‘Limb lead disconnected’

This usually means that one or two of the limb leads are struggling to gain a connection with your patient. Start by checking the right arm and left leg limb leads. If either of these two leads have a problem the machine will not be able to give you any traces.
If still having problems, it may indicate an issue with the electrode contact to your patient. Usually this means there maybe something on the patient’s skin blocking contact, or the gel in the electrode is dry.
Remove all limb lead electrodes from your patient. Clear the areas of any residual gel from the electrodes using an alcohol wipe and dry with a paper towel. This should also remove anything on the patient’s skin that may have previously been blocking contact with the electrode.
Once done apply a fresh set of electrodes from a brand-new unopened packet.

The ECG trace has a lot of interference and the machine is reporting a muscle tremor.

The quality of an ECG trace depends on a few factors but one of the biggest is patient comfort an... Read More

The ECG trace has a lot of interference and the machine is reporting a muscle tremor.

The quality of an ECG trace depends on a few factors but one of the biggest is patient comfort and relaxation. If the patient is tense, struggling to relax, or is in an uncomfortable position this is reflected by interference on the ECG. This Is known as muscle tremor.
There are a few things you can try to mitigate the problem and reduce the interference.
1. Wherever possible attempt to adjust the bed or patient position to make them as comfortable as possible.
2. If the patient is elderly, very muscular, or struggling to relax their limbs and you are using the wrist and ankle limb lead positions, consider moving those attachments to the hips and clavicle. This focuses on much stiller parts of the body that patients have an easier time relaxing.
3. Avoid advising the patient to remain ‘Still’. Most patients will take this to mean go rigid and at this point tense up. Instead, try advising the patients ‘Go Floppy’. This causes the patient to release any tension.
4. This machine does have an inbuilt muscle filter which will desensitise the machine to this kind of interference. We don’t usually recommend using option, because desensitising the machine can mask some conditions from appearing on the ECG, but you are free to use this as a last resort option. To Access the muscle filter, while viewing the ECG trace press ‘F4’ for more options and then ‘F1’ becomes the filter. Press this button until you see ‘100Hz’.
Evidently if the patient is nervous and struggling to relax while having an ECG taken then you may still get a little interference, you may want to seek clinical guidance if this continues to be an issue.

Mac

User Guides and Downloads

Contact Us

Live Support

You can chat to one of our technical support team Monday – Friday 8.00am – 5.30pm.


Service Request

If you would like to request a service for your equipment then please click below.

Contact our Technical Support Team

Our technical support team are available Monday- Friday 8.00am – 5.30pm

Mec0114 399 0010support@numed.co.uk

This license is not a sale of the Manual and you do not become the owner of the Manual through your purchase of any product, download and/or use. Nikon retain ownership of the Manual and all copies thereof and all related intellectual property rights, and reserves all rights not expressly granted to you under this Agreement. This Agreement constitutes the complete and exclusive agreement, oral or written, between you and Nikon.

1. MANUAL

The Manual are for customers who have purchased our products. We may be unable to respond to inquiries from individuals who have not purchased our products. Please note that the manual and the contact information therein are subject to change without notice.

The Manual is protected by Japanese copyright law and international copyright laws and treaties. You must reproduce on each copy the Nikon copyright notice and any other proprietary legends that were on the original.

2. RESTRICTIONS

Except as otherwise stated in this Agreement, you may not make or distribute copies of the Manual to others or electronically transfer the Manual from one computer to another over a network. YOU MAY NOT ALTER OR REMOVE ANY COPYRIGHT, TRADEMARK OR OTHER PROTECTIVE NOTICES CONTAINED IN THE MANUAL. YOU MAY NOT ASSIGN OR OTHERWISE DISPOSE OF, MODIFY, ADAPT, TRANSLATE, RENT, LEASE, LOAN, RESELL, DISTRIBUTE, NETWORK, OR CREATE OR HAVE CREATED DERIVATIVE WORKS BASED UPON THE MANUAL OR ANY PART THEREOF.

3. LIMITED WARRANTY AND DISCLAIMER

TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW, THE MANUAL IS PROVIDED ON AN 'AS IS' BASIS, WITHOUT WARRANTY OF ANY KIND, AND NIKON, ITS EMPLOYEES, DISTRIBUTORS, DEALERS AND AGENTS SPECIFICALLY DISCLAIM ANY WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW, NIKON, ITS EMPLOYEES, DISTRIBUTORS, DEALERS, AND AGENTS DO NOT WARRANT THE PERFORMANCE OF OR THE RESULTS YOU MAY OBTAIN FROM THE MANUAL, OR THAT THE MANUAL WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF THE MANUAL WILL BE UNINTERRUPTED, ERROR-FREE, OR FREE OF VIRUSES. TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW, NEITHER NIKON, NOR ITS EMPLOYEES, DISTRIBUTORS, DEALERS OR AGENTS SHALL BE LIABLE TO YOU FOR ANY INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES, LOSSES OR, EXPENSES OF ANY KIND, WHETHER LOSS OF PROFITS, BUSINESS INTERRUPTION, OR OTHERWISE ARISING OUT OF OR RESULTING FROM THE MANUAL, HOWEVER CAUSED, EVEN IF NIKON, ITS EMPLOYEES, DISTRIBUTORS, DEALERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, LOSSES, OR EXPENSES. THIS DISCLAIMER CONSTITUTES AN ESSENTIAL PART OF THIS AGREEMENT AND NO USE OF THE MANUAL IS AUTHORIZED EXCEPT UNDER THIS DISCLAIMER.

4. GENERAL

This Agreement is governed by and shall be construed in accordance with the laws of Japan without regard to its conflicts of laws principles. In the event a dispute arises under or in connection with this Agreement, you hereby consent to personal jurisdiction of Japan and waive any objection that such forum is inconvenient. You further consent to service of process in any action arising from this Agreement by regular mail or other commercially reasonable means of receipted delivery. If any provision of the Agreement shall be determined invalid for any reason, the remaining provisions shall not be invalidated and shall remain in full force and effect. This Agreement sets forth the entire agreement and understanding between you and Nikon, and supersedes and replaces any other agreements relating to the subject matter of this Agreement. The failure of any party to insist upon strict performance of any of the terms or provisions of this Agreement, or the exercise of any option, right or remedy contained herein, shall not be construed as a waiver of any future application of such term, provision, option, right or remedy, and such term, provision, option, right or remedy shall continue and remain in full force and effect. The headings of the sections of this Agreement are inserted for convenience only and shall not constitute a part hereof or affect in any way the meaning or interpretation of this Agreement. Except as otherwise expressly provided herein, the provisions of section 3 and section 4 together with any provisions that by their express terms apply to periods after termination of this Agreement, shall survive termination of this Agreement for any reason.

Manuals for Nikon products/ 2018/02/15/ Ver.2.0.0